Laboratory drying ovens

High quality modern laboratory drying ovens for all your sterilizing needs. 

Find a distributor
  • Automatic safety thermostat                                                           
  • LCD display - explanatory text boxes
  • Automatic air valve setting
  • Motorised valve
  • Touch buttons
  • Software
  • Extended temperature range up to 250C
  • PID temperature controller
  • Timer
  • Data logging
  • Real time program - two temperatures
  • Keypad with pin code
  • Potential free alarm contact
  • Same regulator for TS and B models
  • 10 speed fan
  • USB Outlet
  • 70mm mineral wool insulation
  • Low energy consumption

SERIES 9000: LABORATORY DRYING OVENS – STERILIZERS

Models: Temperature controlTS 9026TS 9053TS 9135TS 9430
Temperature variation (time) +/- ºC 1 1 1 1
Temperature deviation (spatial) +/- % 1,5 1,5 1,5 1,5
Readability/setability ºC 1 1 1 1
Temperature range   * ºC tb-250 tb-250 tb-250 tb-250
Sensor thermo-couple type K Yes Yes Yes Yes
Controller PID PID PID PID
Display LCD LCD LCD LCD
TimerTS9026TS 9053TS 9135TS9430
Standard hours/minutes 99/59 99/59 99/59 99/59
Real time program Yes Yes Yes Yes
SafetyTS 9026TS 9053TS 9135TS 9430
Alarm flashing / acoustic  Yes  Yes Yes  Yes 
Alarm limit settable  Yes Yes  Yes  Yes 
Automatic safety setting  Yes Yes  Yes  Yes 
FeaturesTS 9026TS 9053TS 9135TS 9430
Fan speed control 1/10 1/10 1/10 1/10
Exhaust valve    mm  30x30 30x30 30x30 60x60
Ventilation slide    0-100% Yes Yes Yes Yes
Data port, Serial    USB Yes Yes Yes Yes
Pot.free alarm output Yes Yes Yes Yes
ShelvesTS 9026TS 9053TS 9135TS 9430
Standard/max    pcs 2/7 2/8 3/16 3/23
Dimensions WxD    mm 346x235 434x325 534x325 602x570
Max load per shelf    kg 20 20 20 30
Permitted total load    kg 50 50 70 100
HeatingTS9026TS 9053TS 9135TS9430
Heating up time to 250C     mins 40 50 65 20
Heat transfer at 250C    W 400 460 710 1500
Air changes    Hz 110 50 20 60
PowerTS9026TS 9053TS 9135TS9430
Nominal power    W 930 1430 1430 4600
Nominal voltage     V   230,1~ 230,1~ 230,1~ 230/400,3~
Frequency    Hz 50/60 50/60 50/60 50/60
DimensionsTS9026TS 9053TS 9135TS9430
Exterior WxDxH    mm 490x480x500 580x575x550 680x675x750 753x845x1360
Interior WxDxH    mm  350x255x300 440x345x350 540x455x555 610x600x1180
Volume    litres 26 53 135 430
Weights/volumeTS9026TS 9053TS 9135TS9430
Net weight    kg 20 35 52 120
Shipping weight    kg  25 40 60 140
Shipping volume    dm3 0,21 350 558 1280
 
tb = 2°C above ambient
* Can be set between two temperatures daily or weekly

 

TS 9053 - open  TS 9053 

 

At what temperature and time should I operate a hot air sterilizer?

The critical process parameters for dry air sterilization are temperature and time. Temperatures below 160°C will not give a satisfactory result. Holding time at 160°C is 2 hours, alternative 180° and 30 minutes holding time.

Temperatures above 180°C can harm instruments over time.

I have limited space. Can I stack the cabinets?

The three smallest models in series 9000 are table models and can be stacked on top of each other. 

I  would like to inspect the goods without opening the door. What can you offer?

The two largest models can be provided with glass in the door. An internal light for better viewing of the goods can also be provided.

Can you deliver the cabinets with castors instead of adjustable feet?

The cooling incubators KB 8000 and climatic cabinets/environmental chambers KB 8400 F are already provided with castors, all of them lockable. Other models can also be provided with castors as an extra option.