Key features of cooled incubator series 8000

  • Low dehumidification
  • Simple operation
  • Programmable, 20 temperatures
  • Alarm
  • Data logging
  • Ramping
  • Automatic safety thermostats
  • Digital calibration
  • Temp. range -9,9 - 70°C
  • 2 sizes, 182 and 400 litres. 

SERIES 8000: Cooling incubators

Temperature controlKB8182KB8400KB8400L
Temperature variation (time) +/- ºC 0,1 0,1 0,2
Temperature deviation (spatial) +/- % 0,2 0,2 0,3
Readability/setability ºC 0,1 0,1 0,1
Temperature range *** ºC -9,9 - 70 -9,9 - 70 -9,9 - 70
Sensor thermo-couple type K Type K Type K Type K
Controller PID PID PID
Display LED LED LED
Adjustable alarm limites (visual and acoustic) Yes Yes Yes
Safety themostats                     KB8182KB8400KB8400L
Temperatire variation (time) +/-C 3 3 3
Sensor thermocouple Type K Type K Type K
Automatic setting Yes Yes Yes
Adjustable limits Yes Yes Yes
       
Light controlKB8182KB8400KB8400L
Readability/setability%     0-100
Light intensity in centreLux     12000
Light intensity both sidesLux     25000
       
AccessoriesKB8182KB8400KB8400L
Automatic de-icing system Adjustable ** Adjustable ** Adjustable **
Timer (1-999 minutes or hours) Yes Yes Yes
Real Time Program Optional* Optional* Optional*
Printer Report Program Optional* Optional* Optional*
Serial Data Port RS232 Yes Yes Yes
Inspection window in door Optional Optional Optional
Inspection window in door with cover  Optional Optional Optional
 2x24 characters LCD display  Yes Yes   Yes
Access port 30mm Optional Optional Optional
Castors, lockable Yes Yes Yes
ShelvesKB8182KB8400KB8400L
Standard / max 3 (14) 3 (22) 3 (22)
Dimensions w-d     mm 500 x 450 610 x 580 610 x 580
Max load pr shelf     kg 20 30 30
Permitted total load     kg 120 120 120
       
Power consumptionKB8182KB8400KB8400L
Nominal power       W 950 950 1200
Nominal voltage     V 230, 1~ 230, 1~ 230, 1~
Frequency               Hz 50/60 50/60 50/60
 
DimensionsKB8182KB8400KB8400L
Exterior W-D-H    mm 680-580-1430 830-720-1840 960-720-1840
Interior W-D-H    mm 520-451-777 630-592-1072 630-592-1073
Volume working chamber    liters 182 400 400
WeightsKB8182KB8400KB8400L
Net weight    kg 95 180 210
Shipping weight    kg 120 210 240
Shipping dimensions W-D-H    mm 760-660-1600 910-800-2010 1040-800-2010
Shipping volume     dm3 803 1463 1672
 
The technical data specified is for an empty cabinet and ambient temperature of 23°C.
* This option is stored in the system and can be freely tested for 30 days. A unique code is then needed in order to make it available for permanent use.
** Temperature limit, de-icing duration and rate can be adjusted. At low temperatures this system will affect the temperature control.
*** Ice build up may occur on the cooler at long runs below 0°C. With 100% light, min temp is +5 °C
 
 
 
 

Cooling incubators KB8182 - KB8400

Cooling incubators KB8182 - KB8400 KB8182 - open door
KB8400 - inside view  

I like to inspect the goods without opening the door. What can you offer?

Most of the cabinets can be provided with double (TS models) or triple (B and KB models) glass in the door. An internal light for better viewing of the goods can also be provided in some of the models.

Can you deliver the cabinets with castors instead of adjustable feet?

The cooling incubators KB 8000 and climatic cabinets/environmental chambers KB 8400 F are already provided with castors, all of them lockable. All other floor models can also be provided with castors as an extra option.

 KB8182KB8400KB8400L
Automatic de-icing system Adjustable ** Adjustable ** Adjustable **
Timer (1-999 minutes or hours) Yes Yes Yes
Real Time Program Optional* Optional* Optional*
Printer Report Program Optional* Optional* Optional*
Serial Data Port RS232 Yes Yes Yes
Inspection window in door Optional Optional Optional
Inspection window in door with cover Optional Optional Optional
 2x24 characters LCD Display Yes  Yes  Yes 
Access Port 30mm Optional Optional Optional
Castors, lockable Yes Yes Yes

 

* This option is stored in the system and can be freely tested for 30 days. A unique code is then needed in order to make it available for permanent use.
** Temperature limit, de-icing duration and rate can be adjusted. At low temperatures this system will affect the temperature control.